+(84) 839 606 568Thermal Dispersion Flow Switch, pressure limits:300 psig (20.67 bar), enclosure rating:NEMA 4X (IP65).
| Service: | Compatible water-based fluids. |
| Wetted Materials: | 316 SS |
| Setpoint Range: | 0.5 to 10 ft/s (0.15 to 3.0 m/s). |
| Repeatability: | 0.07 ft/s +3% of setpoint. |
| Typical Deadband: | 0.1 ft/s +15% of setpoint. |
| Temperature Limits: | Ambient: 5 to 140°F (-15 to 60°C); Process: 5 to 140°F (-15 to 60°C); Storage: -40 to 185°F (-40 to 85°C). |
| Pressure Limits: | 300 psig (20.67 bar) |
| Response Time: | Approximately 8 s. |
| Power Requirement: | 9 to 24 VDC. |
| Switching Current: | 400 mA, derate 5 mA/°C above 23°C. |
| Current Consumption: | Average: 93 mA, Peak: 300 mA. |
| Electrical Connection: | 1/2" NPT cable gland with 4 conductor 22 AWG, 6' (1.83 m) cable. |
| Process Connection: | 1/2" NPT male. |
| Enclosure Rating: | NEMA 4X (IP65). |
| Housing Materials: | 316 SS, 416 SS, polycarbonate, neoprene, and acrylated urethane. |
| Switch Type: | 1 NO NPN, 1 NC NPN. |
| Input Power and Protection: | 0.5A fuse (resettable) reverse polarity protected. |
| Switched Output Protection: | 0.5A fuse (resettable) reverse polarity protected. |
| Agency Approvals: | CE |
Posted by Lam Thanh
The Series VF Visi-Float Acrylic Flowmeters are a line of direct reading, precision machined, clear acrylic body flowmeters suitable for both gas and liquid applications. This Series consists of 2" (51 mm) and 4" (102 mm) scales with optional precision metering valves. Visi-float acrylic flowmeters: series VF DWYER Explore now
Program, record, analyze, and control flow rates of various gases with Series DMF Digital Mass Flow Controller. Controllers are designed with straight tube sensors with restrictor flow elements to ensure laminar gas flow for accurate and repeatable results. Digital mass flow controller: Series DMF DWYER Explore now
The Series RM Rate-Master Polycarbonate Flowmeter are a line of general use, direct reading precision flowmeters suitable for both gas and liquid applications. This Series consists of 2" (51 mm), 5" (127 mm) and 10" (254 mm) scales that can be panel or surface mounted with optional precision metering valves. Rate-master polycarbonate flowmeters: Series RM DWYER Explore now
The SERIES V8 Flotect® Vane Operated Flow Switches is ideal for protecting unattended equipment from damage or loss of production. This Series is available for installation in a 1 to 6" pipe with operating pressures are up to 150 psig (10 bar) and temperatures to 212°F (100°C). Flow switches: Series V8 DWYER Explore now Address: 729 Ba Thang Hai St., Dien Hong Ward, HCM City
Email: info@bkic.vn
Website: https://bkic.vn
Address: No. 4, Street 59, Binh Trung Ward, Ho Chi Minh
Email: info@bkic.vn
Website: https://bkic.vn
Address: No. 35, Lane 45, Tran Thai Tong Street, Cau Giay Ward, Ha Noi
Email: info@bkic.vn
Website: https://bkic.vn