+(84) 839 606 568Field-adjustable insertion thermal energy meter that uses electromagnetic technology to accurately and reliably measure fluid velocity and energy consumption
| Service | Compatible clean or dirty non coating, conductive liquids. |
| Range | 0 to 20 ft/s (0 to 6 m/s).* |
| Wetted Materials | Body shaft/fitting: 316 SS; Electrodes: 316 SS; Electrode cap: Polymer/polystyrene; O-ring: Silicone; Thermowells: 304 SS |
| Accuracy | High Accuracy Units: Class 2 for 2 to 20 ft/s (0.6 to 6 m/s)**; Standard Accuracy Units: Class 3 for 6.5 to 20 ft/s (2 to 6 m/s)** |
| Flow Sensor Accuracy | High Accuracy Units: ±0.5% of reading at calibrated velocity, ±1% of reading from 2 to 20 ft/s (0.6 to 6 m/s) ±0.02 ft/s (±0.006 m/s) at < 2 ft/s (0.6 m/s); Standard Accuracy Units: ±1% FS |
| Temperature Accuracy | Ambient: -20 to 160°F (-29 to 71°C)**; LCD -4 to 158°F (-20 to 70°C); Process: 15 to 250°F (-9 to 121°C); Storage: -40 to 185°F (-40 to 85°C). |
| Process Connection | Flowmeter: 1˝ NPT or BSPT with accessory full port ball valve options; Thermowell: (2) 1/2˝ NPT or BSPT thermowell with 1˝ full port ball valve options |
| Pressure limit | 400 psi (27.6 bar) @ 100°F (37.8°C) |
| Pressure Drop | < 0.1 psi at 12 ft/s in 4˝ (<0.01 bar at 3.7 m/s in 100 mm) and larger pipe. |
| Outputs | (1) Analog: 4-20 mA, 0-5 V, 0-10 V or 2-10 V (display selectable); (1) Pulse/Frequency: 0-15 V peak pulse, 0 to 500 Hz or scalable pulse output (display selectable) |
| (2) Alarm: Empty pipe detection or minimum/maximum velocity, (display selectable) & Reverse flow output indication | |
| Power Requirements | 12-42 VDC, .25 A @ 24 VDC; 12-36 VAC |
| Electrical Connection | Removable terminal blocks, (2) model selectable 1/2˝ female NPT conduit connection, (2) PG 16 gland or (2) PG 16 gland with 10 ft (3 m) 9 conductor 22 AWG plenum rated cables, accessory cable lengths up to 200 ft (61 m) optional. |
| Display (-LCD option) | 2 x 2˝ (50 x 50 mm) graphic LCD with backlight |
| Enclosure Material | Powder coated die cast aluminum |
| Enclosure Ratings | NEMA 6P (IP68) (Non display models); NEMA 4X (IP66) (-LCD option) |
| Agency Approvals | BTL |
Published by Lam
The Series VF Visi-Float Acrylic Flowmeters are a line of direct reading, precision machined, clear acrylic body flowmeters suitable for both gas and liquid applications. This Series consists of 2" (51 mm) and 4" (102 mm) scales with optional precision metering valves. Visi-float acrylic flowmeters: series VF DWYER Explore now
The SERIES TUF Ultrasonic Energy Meters are highly accurate and stable energy meter that utilizes ultrasonic technology to measure heating and cooling energy consumption. The Series TUF is a compact meter with a flowmeter and energy calculator in one, making it great for installation on chillers and boilers. Ultrasonic energy meter: Series TUF DWYER Explore now
The Series RM Rate-Master Polycarbonate Flowmeter are a line of general use, direct reading precision flowmeters suitable for both gas and liquid applications. This Series consists of 2" (51 mm), 5" (127 mm) and 10" (254 mm) scales that can be panel or surface mounted with optional precision metering valves. Rate-master polycarbonate flowmeters: Series RM DWYER Explore now Address: 729 Ba Thang Hai St., Dien Hong Ward, HCM City
Email: info@bkic.vn
Website: https://bkic.vn
Address: No. 4, Street 59, Binh Trung Ward, Ho Chi Minh
Email: info@bkic.vn
Website: https://bkic.vn
Address: No. 35, Lane 45, Tran Thai Tong Street, Cau Giay Ward, Ha Noi
Email: info@bkic.vn
Website: https://bkic.vn