+(84) 839 606 568The Series UFM2 Compact Ultrasonic Flowmeters are economical, clamp-on, ultrasonic flowmeters. The UFM2 implements the transit-time difference to measure flow rates in pipes and can measure velocity and flow in pipes with outside diameters ranging from 3/4 to 7″ (25 to 180 mm). This model comes with a volume pulse and 4-20 mA flow rate output
| Service: | Clean air and non-combustible, compatible gases. |
| Wetted Materials: | Consult factory. |
| Housing Material: | Polycarbonate |
| Accuracy: | ±0.5% FSO for all ranges, except 0.5 in w.c. @ ±1% FSO, and ranges at or below ±0.25 in w.c. @ ±1.5% FSO. |
| Stability: | < ±1% / year FSO. |
| Pressure Limits: | Ranges > 1 in w.c.: 6 psi max operation, 6 psi burst; Ranges ≤ 1 in w.c.: 3.6 psi max operation, 6 psi burst. |
| Temperature Limits: | -4 to 158°F (-20 to 70°C). |
| Thermal Effects: | 0.02% FS / °F (.036% FS / °C). |
| Power Requirements: | 12-28 VDC or 12-28 VAC 50 to 400 Hz. |
| Output Signal: | 4-20 mA (4-wire); 0-10 V, 0-5 V, 1-5 V, and 2-10 V (4-wire). |
| Communication: | BACnet MS/TP or Modbus® RTU. |
| Supported Baud Rate: | 9600, 19200, 38400, 57600, 76800, 115200. |
| Response Time: | 400 ms (damping set to 0). |
| Display: | Backlit LCD display, LED setpoint indicators. |
| Electrical Connections: | 15 pin male high density D-sub connection. 18" (46 cm) cable with 15 conductors included. |
| Process Connections: | 1/8" female NPT ports on side and back. |
| Enclosure Rating: | NEMA 4X (IP66). |
| Size: | 5" OD (127 mm) x 1.9" (48 mm) deep. |
| Compliance: | BTL, CE. |
| CÁC THÔNG SỐ KỸ THUẬT PHỤ | |
| Applicable Pipe Material: | Steel, copper or plastic |
| Pipe Outside Diameter: | 0.98 to 4.62" (24.89 to 117.35 mm) |
| Applicable Pipe Lining: | None |
| Pipe Wall Thickness: | 0.02 to 0.39" (0.5 to 10 mm) |
Program, record, analyze, and control flow rates of various gases with Series DMF Digital Mass Flow Controller. Controllers are designed with straight tube sensors with restrictor flow elements to ensure laminar gas flow for accurate and repeatable results. Digital mass flow controller: Series DMF DWYER Explore now
The Series VF Visi-Float Acrylic Flowmeters are a line of direct reading, precision machined, clear acrylic body flowmeters suitable for both gas and liquid applications. This Series consists of 2" (51 mm) and 4" (102 mm) scales with optional precision metering valves. Visi-float acrylic flowmeters: series VF DWYER Explore now
The Series RM Rate-Master Polycarbonate Flowmeter are a line of general use, direct reading precision flowmeters suitable for both gas and liquid applications. This Series consists of 2" (51 mm), 5" (127 mm) and 10" (254 mm) scales that can be panel or surface mounted with optional precision metering valves. Rate-master polycarbonate flowmeters: Series RM DWYER Explore now Address: 729 Ba Thang Hai St., Dien Hong Ward, HCM City