+(84) 839 606 568The SERIES PFT Insertion Paddlewheel Flowmeters are used to monitor liquid flow rates in pipes from 1-1/2 to 40″ and is available in brass or 316 SS body.
| Service: | Water-based fluids. |
| Range: | 1.2 to 25 ft/s (0.37 to 7.62 m/s). |
| Wetted Materials: | Body and fitting: Brass or 316 SS; Fitting O-ring: FKM standard, silicone or Buna-N optional; Impeller: 316 SS; Shaft: tungsten carbide standard or 316 SS optional; Bearing: PTFE standard. |
| Linearity: | ±1.0% of FS. |
| Repeatability: | ±0.5% of FS. |
| Temperature Limits: | -40 to 212°F (-40 to 100°C). |
| Pressure Limits: | 400 psig (27.6 bar) @ 100°F (37.8°C), 325 psig (22.4 bar) @ 212°F (100°C). |
| Process Connection: | 1-1/2" NPT male standard, 2" NPT male optional. |
| Output: | > Pulse: NPN open collector with square wave output, rated 60 V @ 50 mA maximum. Frequency: 3.2 to 200 Hz. Pulse Width: 2.5 msec ±25%. 4 to 20 mA: 4 mA is 0 ft/s, 20 mA is 25 ft/s. |
| Power Requirement: | 10 to 35 VDC. |
| Power Consumption: | 40 mA (max). |
| Electrical Connection: | 22 AWG shielded UL type PTLC rated 105°C, 20' (6.1 m) long with cable gland. Can be extended up to 2000' (609 m) with similar cable. Optional UL listed burial rated cable. |
| Enclosure Rating: | NEMA 6P (IP67) *. |
| Housing Materials: | Brass or 316 SS. |
| Weight: | 3 lb. (1.36 kg). |
| Agency Approvals: | CE. *Brass units IP67 only. |
Posted by Tuan
The Series UFM2 Compact Ultrasonic Flowmeters are economical, clamp-on, ultrasonic flowmeters. The UFM2 implements the transit-time difference to measure flow rates in pipes and can measure velocity and flow in pipes with outside diameters ranging from 3/4 to 7" (25 to 180 mm). This model comes with a volume pulse and 4-20 mA flow rate output Compact ultrasonic flowmeter: Series UFM2 DWYER Explore now
The SERIES V8 Flotect® Vane Operated Flow Switches is ideal for protecting unattended equipment from damage or loss of production. This Series is available for installation in a 1 to 6" pipe with operating pressures are up to 150 psig (10 bar) and temperatures to 212°F (100°C). Flow switches: Series V8 DWYER Explore now Address: 729 Ba Thang Hai St., Dien Hong Ward, HCM City