Insertion thermal energy meter: Series IEFB DWYER

Field Adjustable, BACnet/Modbus® Outputs

Application

  • Monitoring chiller cooling output performance
  • Industrial boiler heating performance
  • Energy efficiency monitoring
  • Optimization of heat energy performance
  • Commercial and residential heat energy consumption and metering
  • District heating and cooling monitoring
  • Energy cost allocation monitoring
 
IEFB Catalog IEFB IOM (+84) 903 999 357

Field-adjustable insertion thermal energy meter that uses electromagnetic technology to accurately and reliably measure fluid velocity and energy consumption

Detail Up to top

Specification

ServiceCompatible clean or dirty non coating, conductive liquids.
Range0 to 20 ft/s (0 to 6 m/s).*
Wetted MaterialsBody shaft/fitting: 316 SS; Electrodes: 316 SS; Electrode cap: Polymer/polystyrene; O-ring: Silicone; Thermowells: 304 SS
AccuracyHigh Accuracy Units: Class 2 for 2 to 20 ft/s (0.6 to 6 m/s)**; Standard Accuracy Units: Class 3 for 6.5 to 20 ft/s (2 to 6 m/s)**
Flow Sensor AccuracyHigh Accuracy Units: ±0.5% of reading at calibrated velocity, ±1% of reading from 2 to 20 ft/s (0.6 to 6 m/s) ±0.02 ft/s (±0.006 m/s) at < 2 ft/s (0.6 m/s); Standard Accuracy Units: ±1% FS
Temperature AccuracyAmbient: -20 to 160°F (-29 to 71°C)**; LCD -4 to 158°F (-20 to 70°C); Process: 15 to 250°F (-9 to 121°C); Storage: -40 to 185°F (-40 to 85°C).
Process ConnectionFlowmeter: 1˝ NPT or BSPT with accessory full port ball valve options; Thermowell: (2) 1/2˝ NPT or BSPT thermowell with 1˝ full port ball valve options
Pressure limit400 psi (27.6 bar) @ 100°F (37.8°C)
Pressure Drop< 0.1 psi at 12 ft/s in 4˝ (<0.01 bar at 3.7 m/s in 100 mm) and larger pipe.
Outputs(1) Analog: 4-20 mA, 0-5 V, 0-10 V or 2-10 V (display selectable); (1) Pulse/Frequency: 0-15 V peak pulse, 0 to 500 Hz or scalable pulse output (display selectable)
(2) Alarm: Empty pipe detection or minimum/maximum velocity, (display selectable) & Reverse flow output indication
Power Requirements12-42 VDC, .25 A @ 24 VDC; 12-36 VAC
Electrical ConnectionRemovable terminal blocks, (2) model selectable 1/2˝ female NPT conduit connection, (2) PG 16 gland or (2) PG 16 gland with 10 ft (3 m) 9 conductor 22 AWG plenum rated cables, accessory cable lengths up to 200 ft (61 m) optional.
Display (-LCD option)2 x 2˝ (50 x 50 mm) graphic LCD with backlight
Enclosure MaterialPowder coated die cast aluminum
Enclosure RatingsNEMA 6P (IP68) (Non display models); NEMA 4X (IP66) (-LCD option)
Agency ApprovalsBTL
     

Feature

  • Flexible, field configurable setup displays (-LCD integral option or remote accessory A-IEF-DSP) accommodate a variety of application configurations. Application information is display selectable and includes pipe size, pipe material, liquid type, analog output, pulse/frequency output, alarm outputs, communication, outputs, damping, and calibration factor
  • High performance accuracy is maintained through changes in temperature, density and/or viscosity
  • The Setup Wizard and installation tool are simple to use, providing quick and precise installation
  • Accessory setup kit A-IEF-KIT comes with a thickness gage and measuring tape to ensure exact installation depth
  • The meter has no moving parts and electrodes that discourage fouling, which gives the meter a long lifecycle and minimizes the need for maintenance
  • Hot-tap isolation valve accessories allow for easy installation and removal in operational systems without system downtime
     

Published by Lam

Related products Up to top

HEADQUARTERS

Address: 729 Ba Thang Hai St., Dien Hong Ward, HCM City

Email: info@bkic.vn

Website: https://bkic.vn