PM2.5 Transmitter: AVC-210 Series AECL

High-resolution PM2.5 measurement with long-term stability, easily integrated into BMS and ventilation systems for effective air quality monitoring.

Application

  • Commercial building / office.
  • Train station.
  • Shopping Mall.
  • Museum.
  • Hospital.
  • Medical Center.
  • Factory.
  • Library.
  • Indoor places where would be required to detect PM2.5 concentration.
AVC-210_Catalog AVC-210_Manual +(84) 839 606 568

The PM2.5 Transmitter measures particulate matter levels from 0 to 600 μg/m³ with high accuracy, using a state-of-the-art laser scattering sensing element that ensures long-term stability. It is designed for indoor use with a compact, easy-to-install enclosure.

Detail Up to top

Specification

ModelAVC-210
Measuring principleLaser scattering method
Response time≦10 sec.
Counting efficiency98@≧0.5um
Accuracy (at 25℃)0 ~ 100μg/m3 (±10μg/m3);                                                                        100 ~ 600μg/m3 (±10%)
Resolution1 μg/m3
Standard volume0.1 L
Measuring range0 ~ 600μg/m3
Coverage areaAbout 100m2
Signal outputRS485 (Modbus RTU);                                                                            LoRa (Peer to Peer), radio frequency band: 862 ~ 932 MH
Alarm outputRelay output N.O,N.C (2A / 30V DC ; 0.5A / 125V AC);                        Relay setting 50 pp
Calibration interval (recommended)12 months
Sensor lifespan3 years
Pressure range1 atm ± 10 %
Operating environment-10℃ ~ 50℃; 15 ~ 90%RH (non-condensation)
Storage temperature-10℃~ 50℃ (14 ~ 122℉)
Warm-up time≤ 10 Sec
Power supplyDC 12 ~ 36V, AC 24V (50/60Hz)
Power consumptionRS485: 1.1W (Max.); LoRa / RS485: 2W (Max.)
Housing materialFireproof ABS
IP ratingIP30 (No protection from liquids)
CertificationsCE, FCC
  Note:
  • The coverage area should be considered individually to account for the particular layout and any varying or enclosed spaces. It is recommended to install at least one device in each room.
  • The frequency channels will be differed by country and this frequency can be configured accordingly from 862 to 932Hz.
  • The lifespan of sensor might vary depending on environmental conditions. For example, high ambient temperature will shorten its lifespan.
  • The recommended height of installation is 1~2M above the floor level

Feature

  • Measurement: PM2.5
  • Measurement principle: Laser scattering
  • Installation: Wall-mount
  • Protection: IP30
  • Optional bright LCD display.
  • CE & FCC Certifications.
  • Maintenance-free for normal indoor applications.

Related products Up to top

HEADQUARTERS

Address: 729 Ba Thang Hai St., Dien Hong Ward, HCM City

Email: info@bkic.vn

Website: https://bkic.vn

HỒ CHÍ MINH OFFICE

Address: No. 4, Street 59, Binh Trung Ward, Ho Chi Minh

Email: info@bkic.vn

Website: https://bkic.vn

HÀ NỘI OFFICE

Address: No. 35, Lane 45, Tran Thai Tong Street, Cau Giay Ward, Ha Noi

Email: info@bkic.vn

Website: https://bkic.vn