NH3 Transmitter: AVC-410 Series AECL

Ideal for real-time monitoring in environments like public toilets, greenhouses, cold storage plants, and livestock farms where ammonia exposure may be hazardous.

Application

  • Indoor / underground parking.
  • Basement.
  • Restroom.
  • Green House.
  • Hospital.
  • Fertilizer Plant.
  • Livestock Farm.
  • Indoor places where would be required to detect NH3 concentration.
AVC-410_Catalog AVC-410_Manual +(84) 839 606 568

The NH3 Transmitter measures ammonia levels in ambient air using a high-quality electrochemical sensor for reliable and stable performance, with data transmission via RS485 Modbus RTU for ventilation control.

Detail Up to top

Specification

ModelAVC-410
Measuring methodElectrochemical
Response timeτ90≦90 sec
Measurement range0 ~ 50ppm
Accuracy (at 25℃)±5% for 0~50.0ppm
Resolution0.1 ppm
RepeatabilityMeasurement ± 10%
DriftZero:< ±10 ppm /year; Span: < 2% reading /month
Coverage areaAbout 575m2
Signal outputRS485 (Modbus RTU);                                                                            LoRa (Peer to Peer), radio frequency band: 862 ~ 932 MH
Linearity error<10 ppm (at -10℃~ 50℃)
Calibration interval (recommended)12 months
Sensor lifespan2 years
Pressure range1 atm ± 10 %
Operating environment-10℃ ~ 50℃; 0 ~ 95%RH (non-condensation)
Storage temperature-10℃~ 50℃ (14 ~ 122℉)
Warm-up time≤ 1.5 min. (Full scale ≤ 15 min.)
Power supplyDC 12 ~ 36V, AC 24V (50/60Hz)
Power consumptionRS485: 0.1W (Max.); LoRa / RS485: 1.2W (Max.)
Housing materialFireproof ABS
IP ratingIP30 (No protection from liquids)
CertificationsCE, FCC
  Note:
  • The coverage area should be considered individually to account for the particular layout and any varying or enclosed spaces. It is recommended to install at least one device in each room.
  • The frequency channels will be differed by country and this frequency can be configured accordingly from 862 to 932Hz.
  • The lifespan of sensor might vary depending on environmental conditions. For example, high ambient temperature will shorten its lifespan.
  • It is recommended to install about 50cm below ceiling

Feature

  • Measurement: NH3
  • Measurement principle: Electrochemical
  • Installation: Wall-mount
  • Optional bright LCD display.
  • CE & FCC Certifications.
  • Maintenance-free for normal indoor applications.

Related products Up to top

HEADQUARTERS

Address: 729 Ba Thang Hai St., Dien Hong Ward, HCM City

Email: info@bkic.vn

Website: https://bkic.vn

HỒ CHÍ MINH OFFICE

Address: No. 4, Street 59, Binh Trung Ward, Ho Chi Minh

Email: info@bkic.vn

Website: https://bkic.vn

HÀ NỘI OFFICE

Address: No. 35, Lane 45, Tran Thai Tong Street, Cau Giay Ward, Ha Noi

Email: info@bkic.vn

Website: https://bkic.vn

Our clients