H2S Transmitter: AVC-610 Series AECL

Compact design with easy installation, ideal for areas with poor ventilation such as wastewater treatment plants, hot spring pools, and chemical labs.

Application

  • Indoor / underground parking.
  • Basement.
  • Wastewater treatment factory.
  • Food processing plant.
  • Indoor hot spring.
  • Chemical laboratory.
  • Indoor places where would be required to detect H2S concentration.
AVC-610_Catalog AVC-610_Manual +(84) 839 606 568

The H2S Transmitter monitors Hydrogen sulfide in indoor environments with a range of 0 to 50 ppm, providing digital transmission via RS485 using the Modbus RTU protocol for ventilation control.

Detail Up to top

Specification

ModelAVC-610
Measuring methodElectrochemical
Response timeτ90≦60 sec
Measurement range0 ~ 50.0ppm
Accuracy (at 25℃)±5% for 0~50.0ppm
Resolution0.1 ppm
RepeatabilityReading ± 2%
DriftZero:< ±0.1 ppm /year; Span: < 10% reading /year
Coverage areaAbout 525m2
Signal outputRS485 (Modbus RTU);                                                                            LoRa (Peer to Peer), radio frequency band: 862 ~ 932 MH
Linearity error<10 ppm (at -10℃~ 50℃)
Calibration interval (recommended)12 months
Sensor lifespan2 years
Pressure range1 atm ± 10 %
Operating environment-10℃ ~ 50℃ (14 ~ 122℉); 0 ~ 95%RH (non-condensation)
Storage temperature-10℃~ 50℃  (14 ~ 122℉)
Warm-up time≤ 1.5 min. (Full scale ≤ 15 min.)
Power supplyDC 12 ~ 36V, AC 24V (50/60Hz)
Power consumptionRS485: 0.1W (Max.); LoRa / RS485: 1.2W (Max.)
Housing materialFireproof ABS
IP ratingIP30 (No protection from liquids)
CertificationsCE, FCC
Note:
  • The coverage area should be considered individually to account for the particular layout and any varying or enclosed spaces. It is recommended to install at least one device in each room.
  • The frequency channels will be differed by country and this frequency can be configured accordingly from 862 to 932Hz.
  • The lifespan of sensor might vary depending on environmental conditions. For example, high ambient temperature will shorten its lifespan.
  • Easy installation and the recommended height of installation is 30~60cm above the floor leve

Feature

  • Measurement: H2S
  • Measurement principle: Electrochemical
  • Installation: Wall-mount
  • Protection: IP30
  • Optional bright LCD display.
  • CE & FCC Certifications.
  • Maintenance-free for normal indoor applications.

Related products Up to top

HEADQUARTERS

Address: 729 Ba Thang Hai St., Dien Hong Ward, HCM City

Email: info@bkic.vn

Website: https://bkic.vn

HỒ CHÍ MINH OFFICE

Address: No. 4, Street 59, Binh Trung Ward, Ho Chi Minh

Email: info@bkic.vn

Website: https://bkic.vn

HÀ NỘI OFFICE

Address: No. 35, Lane 45, Tran Thai Tong Street, Cau Giay Ward, Ha Noi

Email: info@bkic.vn

Website: https://bkic.vn

Our clients