HCHO Transmitter: AVC-810 Series AECL

Equipped with an industrial-grade Modbus RTU interface, it provides real-time HCHO data to optimize building ventilation and reduce energy consumption

Application

  • Commercial building / office / meeting room.
  • Residential house.
  • Classroom.
  • Train station.
  • Shopping Mall.
  • Indoor places where would be required to detect HCHO concentration.
AVC-810_Catalog AVC-810_Manual +(84) 839 606 568

The AVC-810 HCHO Transmitter uses advanced electrochemical sensing technology to measure formaldehyde gas (0-3ppm) with precision. It features an industrial-standard RS485 interface using the Modbus RTU protocol, enabling continuous monitoring and data transfer for indoor air quality analysis.

Detail Up to top

Specification

ModelAVC-910
Gas typeFormaldehyde (HCHO)
Sensing elementElectro-chemical
Response Timeτ90<120 sec. (HCHO:1ppm)
Accuracy± 5%
Resolution 0.01ppm
Repeatability<±0.05 ppm
DriftZero:<0.05 ppm; Span: < 20% reading /year
Measurement Range0~3.00ppm
Coverage areaAbout 100m2
Output SignalRS-485 (Modbus RTU); LoRa (Peer to Peer), radio frequency band: 862 ~ 932 MHz
Recommended Calibration Interval 12 months
Sensor lifespan > 2 year
Pressure Range1 atm ± 10%
Operating Environment-10°C ~ 50°C (14 ~ 122°F); 0 ~ 95%RH (Non-condensing)
Storage Environment-10°C ~ 50°C (14 ~ 122°F)
Warm-up Time Approximately 5 minutes
Power Supply DC 12 ~ 36V, AC 24V (50/60Hz)
Power ConsumptionRS485: 0.3W (Max); LoRa / RS485: 1.4W (Max)
Housing MaterialFireproof ABS
Protection LevelIP30 (No protection from liquids)
CertificationsCE and FCC
Note:
  • The coverage area should be considered individually to account for the particular layout and any varying or enclosed spaces. It is recommended to install at least one device in each room.
  • The frequency channels will be differed by country and this frequency can be configured accordingly from 862 to 932Hz.
  • The lifespan of sensor might vary depending on environmental conditions. For example, high ambient temperature will shorten its lifespan.
  • Easy installation and the recommended height of installation is 1~2M above the floor leve.

Feature

  • Measurement: HCHO
  • Measurement principle: Electrochemical
  • Installations: Wall-mount
  • Protection: IP30
  • Optional bright LCD display.
  • CE & FCC Certifications.
  • Maintenance-free for normal indoor applications.

Related products Up to top

HEADQUARTERS

Address: 729 Ba Thang Hai St., Dien Hong Ward, HCM City

Email: info@bkic.vn

Website: https://bkic.vn

HỒ CHÍ MINH OFFICE

Address: No. 4, Street 59, Binh Trung Ward, Ho Chi Minh

Email: info@bkic.vn

Website: https://bkic.vn

HÀ NỘI OFFICE

Address: No. 35, Lane 45, Tran Thai Tong Street, Cau Giay Ward, Ha Noi

Email: info@bkic.vn

Website: https://bkic.vn

Our clients