+(84) 839 606 568Air Velocity Transmitter, range: 100, 200, 300, 400 FPM (0.5, 1, 1.5, 2 m/s), accuaracy: 1-2% of reading, enclosure rating: NEMA 4X (IP66).
| Service: | Clean air and non-combustible, compatible gases. |
| Wetted Materials: | Consult factory. |
| Range: | 100, 200, 300, 400 FPM (0.5, 1, 1.5, 2 m/s); field selectable. |
| Accuracy: | See chart. |
| Temperature Limits: | 32 to 122°F (0 to 50°C). |
| Power Requirements: | 24 VDC ±20% or 24 VAC ±20%. |
| Humidity Limits: | 5 to 95% RH, non-condensing. |
| Output Signals: | 4-20 mA, 0-5 VDC, 0-10 VDC. |
| Response Time (90%): | 4 s, typical; 1 s at constant temperature. |
| Zero & Span Adjustments: | Digital push buttons. |
| Output Load Resistance: | Current output: 0 to 1100 Ω max.; Voltage output: Minimum load resistance 1 kΩ. |
| Current Consumption: | 60 mA max. |
| Display: | 5 digit LCD (optional). |
| Electrical Connections: | Analog: Power and output: four wire removable European style terminal block for 16 to 26 AWG; Communication: Connections: BACnet MS/TP or Modbus® RTU/ASCII: three wire removable European style terminal block for 16 to 26 AWG. |
| Supported Communication Baud Rates: | 9600, 19200, 38400, 57600, 76800, 115200 (optional). |
| Device Load: | 1/8 unit load. |
| Electrical Entry: | 1/2˝ NPS thread; Accessory: Cable gland for 5 to 10 mm diameter cable, A-151. |
| Enclosure Rating: | NEMA 4X (IP66). |
| Mounting Orientation: | Flow direction must be parallel to the sensor tip. |
| Weight: | 6.0 oz (160 g). |
| Agency Approval: | BTL, CE. |
The Series CMS300 Carbon Monoxide Transmitter and Switch provides a field selectable current or voltage output that is proportional to the carbon monoxide concentration in underground parking garages, vehicle maintenance facilities, or mechanical rooms. Carbon monoxide transmitter and switch: Series CMS300 DWYER Explore now
THE SERIES GSTC Carbon Monoxide/Nitrogen Dioxide Gas Transmitter monitors the gas concentration in underground parking garages and loading docks. The carbon monoxide transmitter is used to measure the exhaust of gasoline engines, while the nitrogen dioxide transmitter is used for diesel engines. Carbon monoxide transmitters: Series GSTA & GSTC DWYER Explore now Address: 729 Ba Thang Hai St., Dien Hong Ward, HCM City