 (+84) 903 999 357AVC-310 and AVC-311 Series are advanced CO2 sensors utilizing non-dispersive infrared (NDIR) technology for accurate and stable CO2 measurements. The AVC-311 also includes temperature and humidity sensing capabilities, enhancing overall air quality monitoring. Both models support analog outputs, RS485 Modbus RTU interfaces, and SPDT dry contact outputs, making them suitable for applications in HVAC and BMS systems.
| Model: | AVC-310 CO2 Transmitter | AVC-311 CO2, Temperature & Humidity Transmitter | 
| Coverage area | 100m2 | |
| Alarm output | Relay output N.O,N.C ( 2A / 30V DC ; 0.5A / 125V AC) | |
| Pressure dependence | CO2:1.6% reading/kP | |
| Operating conditions | Temperature:-10 ~ 50℃ Humidity:0 ~ 95%RH (non-condensing) | |
| Storage temperature | -20 ~ 70℃ | |
| Warm-up time | ≤ 1 min. (at full specs ≤ 15 minutes) | |
| Power supply | DC 12 ~ 36V AC 24V (50/60Hz) | |
| Sampling interval | CO2 sampling interval:1 sec. | |
| Power consumption | 0~20mA, 4~20mA, 0~10V, 2~10V, RS485:1.6W (Max.) RS485/LoRa:2.4W (Max.) | |
| Installation | Wall-mount , Duct-mount | |
| Case material | Fireproof ABS | |
| Protection | Wall-mount:IP30 (No protection from liquids); Duct-mount:IP65 | |
| Certifications | CE and FCC | |
| Model: | AVC-310 CO2 Transmitter | AVC-311 CO2, Temperature & Humidity Transmitter | 
| Sensing element | CO2: Gold-plated infrared (NDIR) wave-guide technology with Automatic Baseline Correction (ABC) and passive gas diffusion (no moving parts) | CO2: Gold-plated infrared (NDIR) wave-guide technology with Automatic Baseline Correction (ABC) and passive gas diffusion (no moving parts) Temperature & humidity:CMOS sensor | 
| Response time | CO2: < 10 sec. @ 30 cc/min. flow rate < 3 min. diffusion time | CO2: < 10 sec. @ 30 cc/min. flow rate < 3 min. diffusion time Temperature:min. 3 sec.; max. 30 sec. at τ63% Humidity:< 8 sec. at τ63% | 
| Accuracy (at 25℃) | CO2: 0~2000ppm (± 30ppm ±3% of reading), 2001~9999ppm (± 70ppm ±3% of reading) | CO2: 0~2000ppm(± 30ppm ±3% of reading), 2001~9999ppm(± 70ppm ±3% of reading) Temperature:±0.3℃ Humidity: ±2%RH | 
| Repeatability | CO2:± 20 ppm+(±reading *1%) | CO2:± 20 ppm+(±reading *1%) Temperature:±0.1℃ Humidity:±0.1%RH | 
| Zero Drif | CO2: <±10ppm/yr. with Automatic Baseline Correction (ABC) | CO2: <±10 ppm/yr. with Automatic Baseline Correction (ABC) Temperature:< 0.04℃/yr. Humidity:< 0.5 %RH/yr | 
| Measurement range | CO2: 0 ~ 2,000 ppm (Standard) 0 ~ 9999 ppm (High concentration) | CO2: 0 ~ 2,000 ppm (Standard); 0 ~ 9999 ppm (High concentration) Temperature:-10 ~ 50℃; display range:-9.99 ~ 50.00℃ Humidity:0 ~ 100%RH; display range:0 ~ 99.9%RH | 
| Signal output | DC 0~20mA / 4~20mA / DC 0~10V / 2~10V RS485 (Modbus RTU) RS485/LoRa (Peer to Peer), radio frequency band: 862 ~ 932 MHz | RS485 (Modbus RTU) RS485/LoRa (Peer to Peer), radio frequency band: 862 ~ 932 MHz | 
 The AVC-810 HCHO Transmitter uses advanced electrochemical sensing technology to measure formaldehyde gas (0-3ppm) with precision. It features an industrial-standard RS485 interface using the Modbus RTU protocol, enabling continuous monitoring and data transfer for indoor air quality analysis.  HCHO Transmitter: AVC-810 Series AECL Explore now
  The AVC-810 HCHO Transmitter uses advanced electrochemical sensing technology to measure formaldehyde gas (0-3ppm) with precision. It features an industrial-standard RS485 interface using the Modbus RTU protocol, enabling continuous monitoring and data transfer for indoor air quality analysis.  HCHO Transmitter: AVC-810 Series AECL Explore now The AVC-910 TVOC Air Quality Transmitter is designed to measure total volatile organic compounds (TVOCs) ranging from 125 to 600ppb. It features a built-in MEMS metal oxide sensing element for excellent measurement performance and long-term stability. With RS485 signal output via Modbus RTU protocol, it easily integrates with BMS systems.  TVOC Air Quality Transmitter: AVC-910 Series AECL Explore now
  The AVC-910 TVOC Air Quality Transmitter is designed to measure total volatile organic compounds (TVOCs) ranging from 125 to 600ppb. It features a built-in MEMS metal oxide sensing element for excellent measurement performance and long-term stability. With RS485 signal output via Modbus RTU protocol, it easily integrates with BMS systems.  TVOC Air Quality Transmitter: AVC-910 Series AECL Explore now The AVC-010 Oxygen Transmitter is designed to measure oxygen concentration to prevent critical decreases in O2 levels and to control the absence of oxygen in gas mixtures. It utilizes an advanced electrochemical oxygen sensing element to ensure stability and accuracy in measurement.  Oxygen Transmitter: AVC-010 Series AECL Explore now
  The AVC-010 Oxygen Transmitter is designed to measure oxygen concentration to prevent critical decreases in O2 levels and to control the absence of oxygen in gas mixtures. It utilizes an advanced electrochemical oxygen sensing element to ensure stability and accuracy in measurement.  Oxygen Transmitter: AVC-010 Series AECL Explore now The Carbon Monoxide Transmitter uses an electrochemical sensing element to reliably monitor CO concentration in areas such as loading docks, underground parking, basements, garages, or boiler rooms. It offers switchable measurement ranges of 0 to 100ppm and 0 to 250ppm, with an optional high range of 30 to 1000ppm.  Carbon Monoxide Transmitter: AVC-110 Series AECL Explore now
  The Carbon Monoxide Transmitter uses an electrochemical sensing element to reliably monitor CO concentration in areas such as loading docks, underground parking, basements, garages, or boiler rooms. It offers switchable measurement ranges of 0 to 100ppm and 0 to 250ppm, with an optional high range of 30 to 1000ppm.  Carbon Monoxide Transmitter: AVC-110 Series AECL Explore now The wall-mounted PM10 Air Quality Transmitter uses microprocessor and laser scatter sensing technologies for reliable, stable measurements with a response time of ≤ 10 seconds. Its streamlined enclosure allows for flexible installation and maintenance-free operation in typical indoor air quality applications.  PM10 Air Quality Transmitter: AVC-510 Series AECL Explore now
  The wall-mounted PM10 Air Quality Transmitter uses microprocessor and laser scatter sensing technologies for reliable, stable measurements with a response time of ≤ 10 seconds. Its streamlined enclosure allows for flexible installation and maintenance-free operation in typical indoor air quality applications.  PM10 Air Quality Transmitter: AVC-510 Series AECL Explore now The PM2.5 Transmitter measures particulate matter levels from 0 to 600 μg/m³ with high accuracy, using a state-of-the-art laser scattering sensing element that ensures long-term stability. It is designed for indoor use with a compact, easy-to-install enclosure.  PM2.5 Transmitter: AVC-210 Series AECL Explore now
  The PM2.5 Transmitter measures particulate matter levels from 0 to 600 μg/m³ with high accuracy, using a state-of-the-art laser scattering sensing element that ensures long-term stability. It is designed for indoor use with a compact, easy-to-install enclosure.  PM2.5 Transmitter: AVC-210 Series AECL Explore now The AVC-M Indoor Air Quality Transmitter features high-quality sensors for measuring temperature, humidity, CO, CO2, PM2.5, PM10, TVOC, HCHO, oxygen, and NH3. With an RS485 Modbus RTU signal output, it is ideal for HVAC and BMS systems, offering a compact design for flexible integration. Recommended installation height is 1 to 2 meters above floor level.  Indoor Air Quality Transmitter: AVC-M Series AECL Explore now
  The AVC-M Indoor Air Quality Transmitter features high-quality sensors for measuring temperature, humidity, CO, CO2, PM2.5, PM10, TVOC, HCHO, oxygen, and NH3. With an RS485 Modbus RTU signal output, it is ideal for HVAC and BMS systems, offering a compact design for flexible integration. Recommended installation height is 1 to 2 meters above floor level.  Indoor Air Quality Transmitter: AVC-M Series AECL Explore now The Temperature and Humidity Transmitter is perfect for temperature and RH measurement in high humidity environment. Its special metal sintered sensing probe provides protection for the sensing elements and avoids the measurement outage which might happen in high humidity environment.  Temperature Transmitter / Transmitter for Humidity or Dew Point: AHT-5 Series AECL Explore now
  The Temperature and Humidity Transmitter is perfect for temperature and RH measurement in high humidity environment. Its special metal sintered sensing probe provides protection for the sensing elements and avoids the measurement outage which might happen in high humidity environment.  Temperature Transmitter / Transmitter for Humidity or Dew Point: AHT-5 Series AECL Explore now Address: 729 Ba Thang Hai St., Dien Hong Ward, HCM City 
 Email: info@bkic.vn
 Website: https://bkic.vn
 Address: No. 4, Street 59, Binh Trung Ward, Ho Chi Minh 
 Phone: (+84) 903 999 357
 Email: info@bkic.vn
 Website: https://bkic.vn
 Address: No. 35, Lane 45, Tran Thai Tong Street, Cau Giay Ward, Ha Noi 
 Phone: (+84) 915 141 176
 Email: info@bkic.vn
 Website: https://bkic.vn