CO2, Temperature and Humidity Transmitter : AVC-310 & AVC 311 Series AECL

Use NDIR technology for CO2 measurement (0-2,000 ppm, extendable to 9,999 ppm), with the AVC-311 additionally integrating temperature and humidity sensors, supporting analog outputs, RS485 Modbus RTU, and SPDT outputs for fan control or alarms.

Application

  • Commercial building / office / meeting room.
  • Classroom.
  • Train station.
  • Shopping Mall.
  • Warehouse.
  • Museum.
  • Factory.
  • Library.
  • Green House.
  • Laboratory.
  • Mushroom Farm.
  • Wine Cellar.
  • Brewery.
  • Plant factory.
  • Indoor places where would be required to detect CO2 concentration.
AVC-310 & AVC-311_Catalog AVC-311-RS485-Modbus-RTU_Manual AVC-310-RS485-Modbus-RTU_Manual AVC-310-RS485-and-2-10V_Manual AVC-310-CO2-4-20mA_Manual AVC-310-0-20mA-4-20mA-0-10V-2-10V_Manual AVC-310-0-10V_Manual (+84) 903 999 357

AVC-310 and AVC-311 Series  are advanced CO2 sensors utilizing non-dispersive infrared (NDIR) technology for accurate and stable CO2 measurements. The AVC-311 also includes temperature and humidity sensing capabilities, enhancing overall air quality monitoring. Both models support analog outputs, RS485 Modbus RTU interfaces, and SPDT dry contact outputs, making them suitable for applications in HVAC and BMS systems.

Detail Up to top

Specification

Model:                     AVC-310                          CO2 Transmitter                                   AVC-311                                CO2, Temperature & Humidity Transmitter
Coverage area100m2
Alarm outputRelay output N.O,N.C ( 2A / 30V DC ; 0.5A / 125V AC)
Pressure dependenceCO2:1.6% reading/kP
Operating conditionsTemperature:-10 ~ 50℃                                                                                        Humidity:0 ~ 95%RH (non-condensing)
Storage temperature-20 ~ 70℃
Warm-up time≤ 1 min. (at full specs ≤ 15 minutes)
Power supplyDC 12 ~ 36V                                                                                                                      AC 24V (50/60Hz)
Sampling intervalCO2 sampling interval:1 sec.
Power consumption0~20mA, 4~20mA, 0~10V, 2~10V,                                                                      RS485:1.6W (Max.)                                                                                                RS485/LoRa:2.4W (Max.)
InstallationWall-mount , Duct-mount
Case materialFireproof ABS
ProtectionWall-mount:IP30 (No protection from liquids);                                        Duct-mount:IP65
CertificationsCE and FCC
 
Model:                     AVC-310                          CO2 Transmitter                                   AVC-311                                       CO2, Temperature & Humidity Transmitter
Sensing elementCO2:                                                    Gold-plated infrared (NDIR) wave-guide technology with Automatic Baseline Correction (ABC) and passive gas diffusion    (no moving parts)CO2: Gold-plated infrared (NDIR) wave-guide technology with Automatic Baseline Correction (ABC) and passive gas diffusion                                  (no moving parts)                                Temperature & humidity:CMOS sensor
Response timeCO2:                                                    < 10 sec. @ 30 cc/min. flow rate      < 3 min. diffusion timeCO2: < 10 sec. @ 30 cc/min. flow rate                                    < 3 min. diffusion time                                Temperature:min. 3 sec.;                                                                  max. 30 sec. at τ63%              Humidity:< 8 sec. at τ63%
Accuracy (at 25℃)CO2:                                       0~2000ppm                                     (± 30ppm ±3% of reading),               2001~9999ppm                               (± 70ppm ±3% of reading)CO2: 0~2000ppm(± 30ppm ±3% of reading),                      2001~9999ppm(± 70ppm ±3% of reading)                                                  Temperature:±0.3℃                                  Humidity: ±2%RH
RepeatabilityCO2:± 20 ppm+(±reading *1%)CO2:± 20 ppm+(±reading *1%)                Temperature:±0.1℃                                        Humidity:±0.1%RH
Zero DrifCO2: <±10ppm/yr. with Automatic Baseline Correction (ABC)CO2: <±10 ppm/yr. with Automatic Baseline Correction (ABC)                                    Temperature:< 0.04℃/yr.                          Humidity:< 0.5 %RH/yr
Measurement rangeCO2:                                                    0 ~ 2,000 ppm (Standard)              0 ~ 9999 ppm                            (High concentration)CO2: 0 ~ 2,000 ppm (Standard);                                          0 ~ 9999 ppm (High concentration)          Temperature:-10 ~ 50℃;                                                                 display range:-9.99 ~ 50.00℃ Humidity:0 ~ 100%RH;                                                                    display range:0 ~ 99.9%RH
Signal outputDC 0~20mA / 4~20mA / DC 0~10V / 2~10V                                  RS485 (Modbus RTU)                    RS485/LoRa (Peer to Peer), radio frequency band: 862 ~ 932 MHzRS485 (Modbus RTU)                                    RS485/LoRa (Peer to Peer), radio    frequency band: 862 ~ 932 MHz
Note:
  • For general indoor air quality monitoring applications, the accuracy can be achieved after three-week continuous measurement, because of the ABC function. However, in some industrial applications, maintenance or calibration may be required.
  • The accuracy is determined under temperature at 25℃ and barometric pressure at 101.3 kPa, with comparison to the calibrated gas, of which the uncertainty (±1%) is considered.
  • The AVC-31x series is for general indoor use. For any special application, such as industrial or agriculture, please contact us.
  • The frequency channels will be differed by country and this frequency can be configured accordingly from 862 to 932Hz.
  • The coverage area should be considered individually to account for the particular layout and any varying or enclosed spaces. It is recommended to install at least one device in each room.
  • The installation height of wall-mounted type is recommended to be between 1 to 2 meters above the ground.

Feature

  • Measurement: CO2,Temperature, Humidity
  • Measurement principle: CO2: Gold-plated infrared (NDIR) wave-guide / Temperature & Humidity: CMOSens technology
  • Protection: IP30 (Wall-mount) / IP65 (Duct-mount)
  • Optional bright LCD display.
  • CE & FCC Certifications.
  • Maintenance-free for normal indoor applications.

Related products Up to top

HEADQUARTERS

Address: 729 Ba Thang Hai St., Dien Hong Ward, HCM City

Email: info@bkic.vn

Website: https://bkic.vn

HỒ CHÍ MINH OFFICE

Address: No. 4, Street 59, Binh Trung Ward, Ho Chi Minh

Phone: (+84) 903 999 357

Email: info@bkic.vn

Website: https://bkic.vn

HÀ NỘI OFFICE

Address: No. 35, Lane 45, Tran Thai Tong Street, Cau Giay Ward, Ha Noi

Phone: (+84) 915 141 176

Email: info@bkic.vn

Website: https://bkic.vn

Our clients