CO2 Transmitter for High Humidity: AVC-320 Series AECL

The CO2 Transmitter for high humidity uses advanced gold-plated infrared (NDIR) wave-guide technology to accurately measure a large-scale CO2 measurement ranging from 0 to 9999ppm.

Application

  • Green House.
  • Mushroom Farm.
  • Wine Cellar.
  • Brewery.
  • Plant factory.
  • Farms.
  • Storage room.
  • Indoor places where would be required for CO2 detection.
AVC-320_Catalog AVC-320_4-20mA_Manual AVC-320_RS485-Modbus-RTU_Manual +(84) 839 606 568

The Carbon Dioxide Transmitter is specially designed for measuring CO2 in high humidity environment. The featured metal sintered probe of the CO2 Transmitter with IP54 rating could protect the sensing electronics from the damage caused by moisture in the air to extend the life span of the sensing electronics.

Detail Up to top

Specification

Model:AVC-320SAX-MAVC-320S4X-M
Sensing elementGold-plated infrared (NDIR) wave-guide technology with Automatic Baseline Correction (ABC) and passive gas diffusion (no moving parts)
Response time< 10 sec. @ 30 cc/min. flow rate                                                                                      < 3 min. diffusion time
Accuracy (at 25℃)0~2000ppm (± 30ppm ±3% of reading), 2001~9999ppm (± 70ppm ±3% of reading)
Repeatability± 20ppm + (± reading * 1%)
Zero Drif< ± 10ppm/yr. with Automatic Baseline Correction (ABC)
Measurement range0 ~ 9999 ppm
Signal outputDC 4 ~ 20mARS485 (Modbus RTU)
Pressure dependence1.6% reading per kPa
Loading resistanceCurrent output: RL<500Ω at 24V DC
EnvironmentalTemperature: -10 ~ +60℃; Humidity: 0 ~ 99%RH (without condensation)
Storage temperature-20 ~ +70℃
Warm-up time≤ 1 min. (at full specs ≤ 15 minutes)
Power supply20 ~ 36V DC12 ~ 36V DC
Power consumption1.7W (Max.)1.4W (Max.)
InstallationWall-mount
MateriaMain unit: Stainless steel; Fixed support: PE
IP ratingIP54
  • ABC correction will ensure the accuracy with continuous detection of three weeks. However, for some special application, maintenance and calibration would be necessary.
  • The accuracy is applied for indoor temperature 25℃ and normal air pressure 101.3kPa. The specification is based on certified calibrated gas. The variation of mixture gas (as ±1%) will be consider as its accuracy as absolute measurement

Feature

  • Measurement: CO2
  • Measurement principle: Gold-plated infrared (NDIR) wave-guide technology
  • Installation: Wall-mount
  • Protection: IP54
  • Case Material: Stainless

Related products Up to top

HEADQUARTERS

Address: 729 Ba Thang Hai St., Dien Hong Ward, HCM City

Email: info@bkic.vn

Website: https://bkic.vn

HỒ CHÍ MINH OFFICE

Address: No. 4, Street 59, Binh Trung Ward, Ho Chi Minh

Email: info@bkic.vn

Website: https://bkic.vn

HÀ NỘI OFFICE

Address: No. 35, Lane 45, Tran Thai Tong Street, Cau Giay Ward, Ha Noi

Email: info@bkic.vn

Website: https://bkic.vn

Our clients