(+84) 903 999 357Only 0.63″ in diameter making it ideal for level monitoring in well and borehole applications .
| Service: | Compatible liquids. |
| Wetted Materials: | Body and nose: 316 SS; Cable: Polyether polyurethane or ETFE; Seals: Fluoroelastomer; Label: Polyolefin. |
| Accuracy: | ±0.25% or ±0.10% FS. 4.3 to 4.9 psi (10 to 11.54" w.c.) configured ranges are ±0.30% FS accuracy. |
| Temperature Limits: | -4 to 176°F (-20 to 80°C). |
| Compensated Temperature Limits: | 0.25%: (0 to 70°C); 0.10%: (0 to 60°C). |
| Thermal Effect: | 0.25%: ±0.45% FS TEB; 0.10%: ±0.30% FS TEB. |
| Pressure Limit: | 2x FS. |
| Power Requirements: | Current Output: 10 to 33 VDC; Voltage Output: 8 to 33 VDC; 5 mA max (no load). |
| Output Signal: | 4 to 20 mA DC 2-wire or 0 to 5V* (model depending). *Consult factory for additional outputs. |
| Response Time: | < 50 ms. |
| Max Loop Resistance: | 1000Ω @ 30 VDC (current output). |
| Voltage Output Impedence: | 10Ω + 4.4Ω / 100' cable (voltage output). |
| Electrical Connections: | Wire pigtail. |
| Mounting Connection: | Suspended below point being monitored. |
| Electrical Protection: | Surge/lightning protected per EN61000-4-5, Class 5. |
| Weight: | Body: 0.235 lb (0.107 kg); Cable: 0.037 lb (0.009 kg) per foot. |