Dynamic regulating balancing valve Kombi-9 HONEYWELL

Pressure Independent Integrated Balancing Control Valve

Application

Honeywell Kombi-9 is designed for precise temperature control of terminal air-conditioning equipment in the HVAC system. It can maintain the flow regardless of variations in system differential pressure. With the valve position feedback the Building Automation System can always operate in the most energy-saving mode.
Kombi-9-datasheet +(84) 839 606 568
Model: Kombi-9
Origin: Honeywell/Taiwan
PN16, Size: DN25 – DN150

Detail Up to top

Specification

Size range:DN25-DN100
Flow control accuracy:±4%
Max. flow set range:60%~100%*Qr
Max. close-off pressure:10 bar/ DN25, 7 bar/ DN32, 4.6 bar/ DN40, 2.6 bar/ DN50, 10 bar/ DN65-DN150
Difference Range:30~250kPa
Input control signal:0/2 ~ 10VDC 0/4 ~ 20mA
Feedback signal :2~10VDC
Supply voltage:24VAC(+15%,-10%),50/60Hz
Electric connection:1 m operating power cable
Valve rated pressure:PN16
Connection of valve:DN25~DN50: Female screw BSPT DN65~DN150: Flange (ISO7005-2)
Valve body Material:DN25~DN50: Bronze DN65~DN150:Control valve cast iron GG25
Media:Water, glycol solution
Media temperature: -5℃~120℃
Operating ambient:temperature: 0~65°C Atmosphere: Non-corrosive, non-explosive
 
Selection
 SizeQr(m3/h)*Kvs theor.**InterfaceValve & pre- sensor OS#Actuator & Sensor OS#Power consump- tion (VA)
DN253.58.7ThreadedV5011P1004-K9ML7420A8088-SBU6(Operation) 3.5(Standby)
DN32615V5011P1012-K9
DN409.624V5011P1020-K9
DN5016.140.2V5011P1038-K9
DN652663 FlangedV5328A1179-K9
DN8040100V5328A1187-K9
DN10063157.5V5088A1005-K9 ML7421B8012-SBU

12(Operation)

2.6(Standby)

DN125103250V5088A1013-K9
DN150137342.5V5088A1021-K9
 

Feature

  • Integrated functions as linear temperature control, pressure independent and electric regulating into one valve
  • High control accuracy, strong anti-interference capacity
  • Simple calculation in designing the pipeline system
  • Easy installation
  • Extremely convenient for commissioning at site
  • Wide fluctuating range of pressure difference for the system
  • Output the valve position signal to BAS for system variable differential pressure control of variable flow water system, ensure HVAC water system can always operate in the most energy-saving mode
   
Published by Lam

HEADQUARTERS

Address: 729 Ba Thang Hai St., Dien Hong Ward, HCM City

Email: info@bkic.vn

Website: https://bkic.vn

HỒ CHÍ MINH OFFICE

Address: No. 4, Street 59, Binh Trung Ward, Ho Chi Minh

Email: info@bkic.vn

Website: https://bkic.vn

HÀ NỘI OFFICE

Address: No. 35, Lane 45, Tran Thai Tong Street, Cau Giay Ward, Ha Noi

Email: info@bkic.vn

Website: https://bkic.vn

Our clients