+(84) 839 606 568Processor 100 MHz, high-performance, 32-bit embedded microcontroller Memory • 8 MB operating RAM • 1 MB non-volatile RAM (trends and dynamic values) • 4 MB Flash EEPROM operating system, database, and controller configuration Supply Voltages • 24 VAC ±10%, 75 VA max. 50/60 Hz • 24 VDC ±10% 26 W max. Communications • 1 EIA-485…
| Processor | 100 MHz, high-performance, 32-bit embedded microcontroller |
| Memory | • 8 MB operating RAM • 1 MB non-volatile RAM (trends and dynamic values) • 4 MB Flash EEPROM operating system, database, and controller configuration |
| Supply Voltages | • 24 VAC ±10%, 75 VA max. 50/60 Hz • 24 VDC ±10% 26 W max. |
| Communications | • 1 EIA-485 @ 76.8 kbps max. Auto-baud detection • 1 EIA-232 @ 115.2 kbps max. PC or modem • SMART-Net port @ 8 sensors max. |
| Universal Inputs | • 12 universal inputs • 12-bit A/D converter • Analog: 0–10 VDC, 4–20 mA, thermistor • Binary: dry contact • Impedance: 1M W for 0–10 VDC range 250 W for 4–20 mA range 20k W pull-up for thermistor/dry contact range • Pulse counting up to 150 Hz (supports flow meters) • 24 VAC over-voltage protection |
| 8 Outputs | • 12-bit D/A converter • Analog: 0–12 VDC • Binary: 0/12 VDC • Manual ON provides adjustable 0–12 VDC (HOA model only) • LED indicator (glows proportionally) • Output power: 75 mA @ 12 VDC • 24 VAC over-voltage and short protection |
| Peripheral Power | Onboard variable 15–24 VDC power supply providing up to 200 mA of DC power to peripheral devices (if powered by 24 VDC, the maximum voltage output is 22 VDC) |
| Real-Time Clock | ±1 second per day |
| Memory/RTC Backup | • 72 hour backup • 10 years for database |
| SETUP-Tool™ | SETUP-Tool optional for configuration |
| Dimensions | 25.4 cm L x 13.7 cm W x 3.9 cm H (10" L x 5 3/8" W x 1 1/2" H) |
| Mounting | • #8 clearance holes on 23.0 cm L x 11.0 cm W (9 1/16" L x 4 5/16" W) • Screw depth 25 mm (1") |
| Weight | 0.6 kg (1.3 lb) |
| Ambient Limits | • Operating: -20 °C to 55 oC (-4 °F to 131 oF) • Shipping: -40 °C to 60 °C (-40 °F to 140 °F) • Humidity: 10% to 90% RH non-condensing |
| Protocol | BACnet® -- MS/TP and PTP |
| 12 Inputs | • Universal ranges • Jumper selectable 0–10 VDC, 4–20 mA, thermistor/dry contact |
| 8 Outputs | • Universal ranges • Optional HOA (Hand/Off/Auto) switches • HOA position feedback to RC‑Studio® |
| 256 Variables | Selectable standard and custom ranges, as well as fixed program-driven values |
| 32 PID Loops | Standard P, PI, or PID controllers for closed loop control |
| 16 Schedules | 14 On/Off times for each weekday or exception |
| 8 Calendars | Days of the year designated as holidays |
| 20 Custom Tables | For creating custom scaling functions |
| 32 System Groups | • Allows related points to be grouped on to one display • 80 points/group |
| 32 Control-BASIC™ Programs | • User programmable control strategy in a readable, BASIClike language • 3200 bytes per program |
| Trend Logs | • Each Trend Log stores up to 8 points • Values recorded at user-defined intervals • Dynamically assigned |
| Runtime Logs | • Totals the On time and records the On/Off times of every binary point • Holds 200 events • Dynamically assigned |
| 128 Variable Arrays | Up to 128 elements in a onedimensional array |
| 128 User Passwords | • Protects access to system • Each user is assigned a user name and an access level |
| 24 Custom Units | • 8 analog engineering units • 8 binary engineering units • 8 multistate units |
| SMART-Net™ Port | Networks up to 8 SMARTSensors |
| Warranty | 5 years |
| Certification | • BTL Listed (B-BC) • UL916 Listed • FCC CFR 47 Part15/B • CE |
Address: 729 Ba Thang Hai St., Dien Hong Ward, HCM City
Email: info@bkic.vn
Website: https://bkic.vn
Address: No. 4, Street 59, Binh Trung Ward, Ho Chi Minh
Email: info@bkic.vn
Website: https://bkic.vn
Address: No. 35, Lane 45, Tran Thai Tong Street, Cau Giay Ward, Ha Noi
Email: info@bkic.vn
Website: https://bkic.vn