(+84) 903 999 357The SERIES RHP-E/N Wall Mount Humidity/Temperature/Dew Point Transmitter is the most versatile room transmitter on the market. The stylish housing is well vented to provide air flow across the sensor to improve measurement accuracy.
| Relative Humidity Range: | 0 to 100% RH. |
| Temperature Range: | -40 to 140°F (-40 to 60°C) for thermistor and RTD sensors. -20 to 140°F (-28.9 to 60°C) for solid state band gap temperature sensors. |
| Dew Point Temperature Range: | -20 to 140°F (-28.9 to 60°C); 0 to 100°F (-17.8 to 37.8°C); 40 to 90°F (4.4 to 32.3°C); -4 to 140°F (-20 to 60°C) field selectable ranges. |
| Accuracy: | >RH: Model RHP-2XXX ±2% 10-90% RH @ 25°C, Model RHP-3XXX ±3% 20-80% RH @ 25°C; Thermistor temperature sensor: ±0.36°F @ 77°F (±0.2°C @ 25°C); RTD Temperature sensor: DIN Class B; ±0.54°F @ 32°F (±0.3°C @ 0°C); Solid state band gap temperature sensor: ±0.9°F @ 77°F (±0.3°C @ 25°C). |
| Hysteresis: | ±1%. |
| Repeatability: | ±0.1% typical. |
| Temperature Limits: | Operating: -40 to 140°F (-40 to 60°C); Storage: -40 to 176°F (-40 to 80°C). |
| Compensated Temperature Range: | -4 to 140°F (-20 to 60°C). |
| 4-20 mA Loop Powered Output: | >Power Requirements: 10-35 VDC; Output Signal: 4-20 mA, 2 channels for humidity/solid state temperature sensor models (loop powered on RH); Switch selectable RH/dew point. Switch selectable normal or reverse output. |
| 0-5/10V Outputs: | >Power Requirements: 15-35 VDC or 15-29 VAC. Output Load: 5 mA max., 2 channels for humidity/solid state temperature sensor models. Switch selectable 0-10V/2-10V or 0-5V/1-5V output. Switch selectable RH/dew point. Switch selectable normal or reverse output. |
| Solid State Band Gap Temp Sensor Output Ranges: | Switch selectable, -20 to 140°F (-28.9 to 60°C); 0 to 100°F (-17.8 to 37.8°C); 40 to 90°F (4.4 to 32.3°C); -4 to 140°F (-20 to 60°C). (See R-T Lookup Table). |
| Response Time: | 15 seconds. |
| Electrical Connections: | Screw terminal block. |
| Drift: | <1% RH/year. |
| RH Sensor: | Capacitance polymer. |
| Enclosure Material: | Warm gray polycarbonate. |
| Display: | Optional LCD, backlit on 0-5/10V models. Switch selectable %RH or dew point, °F/°C. |
| Display Resolution: | RH: 1%; Temperature: 0.1°F (0.1°C); Dew Point: 1°F (1°C). |
| Weight: | 0.3 lb (0.14 kg). |
| Agency Approvals: | CE. |
Posted by Tuan
THE SERIES GSTC Carbon Monoxide/Nitrogen Dioxide Gas Transmitter monitors the gas concentration in underground parking garages and loading docks. The carbon monoxide transmitter is used to measure the exhaust of gasoline engines, while the nitrogen dioxide transmitter is used for diesel engines. Carbon monoxide transmitters: Series GSTA & GSTC DWYER Explore now
The Series CMS300 Carbon Monoxide Transmitter and Switch provides a field selectable current or voltage output that is proportional to the carbon monoxide concentration in underground parking garages, vehicle maintenance facilities, or mechanical rooms. Carbon monoxide transmitter and switch: Series CMS300 DWYER Explore now Address: 729 Ba Thang Hai St., Dien Hong Ward, HCM City
Email: info@bkic.vn
Website: https://bkic.vn
Address: No. 4, Street 59, Binh Trung Ward, Ho Chi Minh
Phone: (+84) 903 999 357
Email: info@bkic.vn
Website: https://bkic.vn
Address: No. 35, Lane 45, Tran Thai Tong Street, Cau Giay Ward, Ha Noi
Phone: (+84) 915 141 176
Email: info@bkic.vn
Website: https://bkic.vn