Differential pressure gages / switch digital: Series DH3 DWYER

Digihelic® Controller in Photohelic® Gage, Square Root Output for Flow

Application

  • SCFM flow in ducts
  • Filter status
  • Static pressures in ducts or buildings
  • Damper control
  • Fan control
DH3_Catalog DH3_IOM (+84) 903 999 357

3-in-1 instrument possessing a digital display gage, control relay switches, and a transmitter with current output.

Detail Up to top

Specification

Service:Air and non-combustible, compatible gases.
Housing Materials:Die cast aluminum case and bezel.
Accuracy:±1.5% for 0.25" and ±0.25" w.c. ranges. Ranges 0.5" to 5" w.c. and corresponding bi-directional (except ±2.5" w.c.) ±1%; All other ranges: ±0.5% @ 77°F (25°C) including hysteresis and repeatability (after 1 hour warm-up).
Stability:< ±1% per year.
Pressure Limits:Ranges ≤ 2.5 in w.c.: 25 psi; ±2.5", 5 in w.c.: 5 psi; 10 in w.c.: 5 psi; 25 in w.c.: 5 psi; 50 in w.c.: 5 psi; 100 in w.c.: 9 psi.
Temperature Limits0 to 140°F (-18 to 60°C).
Compensated Temperature Limits:32 to 122°F (0 to 50°C).
Thermal Effect:0.020%/°F (0.036/°C) from 77°F (25°C). For 0.25" and ±0.25" w.c. ranges: ±0.03%/°F (±0.054%/°C).
Power Requirements:12 to 28 VDC, 12 to 28 VAC 50 to 400 Hz.
Power Consumption:3 VA max.
Current Consumption:5 mA maximum
Output Signal:4 to 20 mA DC into 900 Ω max.
Zero & Span Adjustments:Accessible via menus.
Response Time:250 ms (damping set to 1).
Display:Backlit 4 digit LCD 0.4" height LED indicators for set point and alarm status.
Electrical Connections15 pin male high density D-sub connection. 18" (46 cm) cable with 10 conductors included. 4' and 10' cables available.
Process Connections1/8" female NPT. Side or back connections.
Mounting Orientation:Mount unit in vertical plane.
Size:5" (127 mm) OD x 3-1/8" (79.38 mm).
Weight:1.75 lb (794 g).
Agency Approvals:CE.
SWITCH SPECIFICATIONS
Switch Type:2 SPDT relays.
Electrical Rating:1 A @ 30 VAC/VDC.
Set Point Adjustment:Adjustable via keypad on face.
 

Feature

  • 3-in-1 instrument allows the reduction of several instruments with one product, saving inventory, installation time and money
  • Secure menu program provides access to device operation only for the right skill level
  • Full scale accuracy of 1% even on extremely low ranges, and 0.5% for ranges above 5 in w.c. provide for greater measurement precision

   

Published by Lam

HEADQUARTERS

Address: 729 Ba Thang Hai St., Dien Hong Ward, HCM City

Email: info@bkic.vn

Website: https://bkic.vn