Differential Pressure Transmitter: ADP Series AECL

Designed for use in applications like negative pressure isolation rooms, mechanical systems, and wind speed measurement with Pitot tubes

Application

  • Commercial building.
  • Laboratory.
  • Smoking room.
  • Clean room.
  • Negative pressure isolation room.
  • Hospital.
  • Medical Center.
  • Indoor places where would be required to measure pressure difference.
ADP-Differential-Pressure-Transmitter ADP_Catalog ADP-0-10V_Manual ADP-4-20mA_Manual ADP-RS485-Modbus-RTU_Manual +(84) 839 606 568

The Differential Pressure Transmitter uses a temperature-compensated CMOSense sensing element to deliver stable and accurate air pressure measurements for non-aggressive gases like N2 and O2. It offers three selectable pressure ranges (-25 to 25 Pa, -125 to 125 Pa, -500 to 500 Pa) and provides analog outputs (0-10V, 4-20mA) along with RS485 Modbus RTU for easy integration with various systems. The IP54-rated enclosure ensures protection in harsh environments.

Detail Up to top

Specification

ModelADP-025ADP-125ADP-500
Detecting method Thermal flow-through principal
Media compatibilityAir, N2, O2
Temperature compensationYes
Response time (T1/e) 4.6 ms typical at 12-bit resolution
Measuring range-25~25 Pa-125~125 Pa-500~500 Pa
Accuracy                                Zero : ±0.1 pa ;                                       Span : ±3% of F.S.   Zero : ±0.2 pa ;          Span : ±3% of F.S.
Repeatability0.5% of F.S
Offset stability < 0.1 pa/ yr.
Signal output                            DC 4 ~ 20mA (Loading resistance ≦500Ω);                                  DC 0 ~ 10 V(Loading resistance ≧50KΩ); RS485 (Modbus RTU)
Display LCM display (3 digits) optional;
Display selection        -25 ~ 25 Pa                         -25 ~ 0 Pa                  0 ~ 25 Pa        -125 ~ 125 Pa                     -125 ~ 0 Pa                 0 ~ 125 Pa        -500 ~ 500 Pa                     -500 ~ 0 Pa                 0 ~ 500 Pa
Withstand pressure 1 bar
Burst pressure> 5 bar
Operating environmental -10°C ~ +60 °C ; 0 ~ 95% RH (non-condensation)
Transportation and storage-20°C ~ +70 °C
Warm-up timeTyp. 50 ms (first measurement typically after 16 ms)
Power supply12 ~ 36V AC/DC,50/60Hz
Power consumption <0.6W ( peak value)
InstallationWall-mount
Dimensions (mm)98(H) x 64(W) x 34(D)
Case materialCast aluminum
Protection rate IP54
 

Feature

  • Media compatibility: Air, N2, O2
  • Measurement principle: Thermal flow-through
  • Protection: IP54
  • Cast Material: Cast aluminum
  • Optional LCD display.
  • CE & FCC Certifications.
  • Maintenance-free for normal indoor applications.

Related products Up to top

HEADQUARTERS

Address: 729 Ba Thang Hai St., Dien Hong Ward, HCM City

Email: info@bkic.vn

Website: https://bkic.vn

HỒ CHÍ MINH OFFICE

Address: No. 4, Street 59, Binh Trung Ward, Ho Chi Minh

Email: info@bkic.vn

Website: https://bkic.vn

HÀ NỘI OFFICE

Address: No. 35, Lane 45, Tran Thai Tong Street, Cau Giay Ward, Ha Noi

Email: info@bkic.vn

Website: https://bkic.vn

Our clients